Methods used for finding slab thickness varies for different types of slabs.
1 story reinforced concrete wall thickness.
Structural concrete work is planned to bear loads or hold weight but transfer the weight to the soil base beneath the structure.
Footing depth varies based on frost line and soil strength some footings can be shallow while other must be deep.
Plain concrete wall when reinforcement 0 4 reinforced concrete wall when reinforcement gt.
So taller walls in heavier soils should be made thicker or with stronger concrete.
Footing thickness 8 to 12 inches.
As soon as you go higher or have greater depths of soil pushing against the wall you need to increase the thickness to 10 inches.
However aci 318 also permits these requirements to be waived in the event that structural analysis demonstrates adequate strength and stability in accordance with aci 318 14 2 7.
Table 4a is based directly on the aci method but for table 4b the author has applied a reduced strength reduction factor a factor of safety.
Thickness of concrete slab depends on loads and size of the slab.
In some situations the rebar is critical to the structural integrity of the wall.
In general 6 inch 150mm slab thickness is considered for residential and commercial buildings with reinforcement details as per design.
Cabo one and two family dwelling code.
Find nearby slab and foundation contractors to help with your.
For example one way slab thickness calculation is different and easier from hellip.
The rebar increases the wall s strength without expanding its thickness.
Poured concrete foundation walls that are less than 8 feet tall and have soil outside that is 6 or 7 feet deep against the wall can often be 8 inches thick and function quite well.
Reinforced concrete wall is designed as a compression member.
Concrete calculator figure out how much concrete you ll need for your footings.
Increasing the strength of the concrete mix or the thickness of the wall increases the wall s capacity.
Aci 318 allows two approaches to the design of reinforced concrete with some limits on wall thickness and the minimum amount of steel reinforcement.
Strength of reinforced concrete sections amount of rebar a s the project calls for 5 10 and 5 12 are used.
Strength reduced from 136 7 to 114 9 in kips.
2 5 clear to strength steel 5 12 rather than the designed 5 10 bending strength of the section has been reduced by about 16.
Reinforced concrete concrete walls that contain steel bars or rebar offer more resistance to external stresses than concrete with no reinforcement.