These wall assembly files are used for planning and estimation purposes for many ul wall types such as fire rated wall assemblies.
1 hour rated wall at roof.
Wood framed including dimensional lumber engineered joist and truss.
Fire rated from one side and from both sides about the assembly.
Usg provides resources here for our ul wall assemblies for seamless integration into any construction project.
12 x 24 2 x 4 8 w10 x 25 beam floor units and beam support 3 hr.
Rated from one side and from both sides.
C roof ceilings45 51 steel framed including steel bar joist framing steel c joist framing steel truss and steel roof deck.
276 fire rated ceiling assemblies suspension ceiling designs floor ceiling designs a003 3 hr.
1 hour wall assembly.
Wall assemblies and table 2 for two hour rated wall assemblies.
Gypsum panel end joints located midway between continuous channels and attached to additional pieces of channels 54 1372 mm long with screws 12 305 mm o c.
D horizontal membrane 52 shaft wall used in a horizontal plane.
Fire resistance ratings are expressed in the number of minutes or hours a structure can withstand a fire simulation test.
1 hour exterior wall assembly ul design no.
2009 irc requires walls built within 5 of a property line or within 5 of another building on the same property to have a 1 hour fire resistance rating with fire exposure from the exterior of the building note.
45 minute rating 45 min floor or roof with insulation 24 oc min 15 depth flat min 19 1 2 depth 3 12 min pitched fr quik channel setstm 1 layer 5 8 type c gypsum sheathing min 15 32 category floor or roof suspended ceiling system illustration fr system 4 tm ner 392 1991 construction 1 hour rating floor or roof 24 oc min 12 depth 2.
3 4 fr 83 12 x 12 z runners fluorescent type none 2 1 2 concrete.
Descriptions of successfully tested i joist floor as semblies are provided in.
According to the engineered wood association a one hour rating indicates that a wall constructed in a manner similar to the one tested will contain flames and high temperatures and support its full load for at least one hour after the fire begins.
1 2 12 7 mm toughrock fireguard c or 1 2 12 7 mm densarmor plus fireguard c gypsum panel applied perpendicular to resilient channels 24 610 mm o c.
With 1 25 mm type s drywall screws 12 305 mm o c.
Urb concealed grid system and tile.
American softwood lumber standard ps 20.
Lumber shall be identified by the grade mark of a lumber grading or inspection agency that has been approved by an accreditation body that complies with the.